—Billi B–4000 system components
1. Underbench module
2. Dispenser tap upper with tubing
3. Dispenser base and mount
4. Barb locking bush
5. 4mm chrome screw and allen key
6. Large washer
7. Tube spring clamps x 3
8. 450mm flexible braided hose
9. Filter cartridge (installed)
10. Billi B–4000 User guide
11. Warranty certificate
—Determine unit location
Plan the installation. Dispenser tube
lengths, position of power and water outlets,
required air space around the underbench
module and access for service must be
considered before cutting tube lengths.
Refer to Diagrams 1, 2 and 3 for clearances
around the dispenser and unit. Unit must be
installed horizontally with plastic vent panel
facing to front of cupboard. The B–4000 is
designed for internal installation only.
—Water supply
The B–4000 must only be connected to a
cold water supply. A 15mm stop tap (not
supplied) is to be installed in an easily
accessible position within 450mm from
the B–4000 water supply inlet.
Supply pressure: 200 – 1000 Kpa
Supply temperature: 5°C – 30°C
DO NOT install with water that is
microbiologically unsafe or with water
of unknown quality without adequate
disinfection before the system. Systems
certified for cyst reduction may be used on
disinfected water that may contain filterable
cysts.
—Ventilation
The B–4000 does not require cupboard
ventilation. Adequate air space and an
unobstructed clearance of at least 25mm
on each side of the underbench unit is
sufficient.
—Power requirements
A single 10 amp standard power outlet
is required. B–4000 module is supplied
with 1 metre of flex cord and plug.
Installation
requirements.
360mm
180mm
360mm
340mm
340mm
180mm
20mm
20mm
Diagram 1 Diagram 2
Diagram 3
60mm minimum
clearance
180mm
340mm
150mm
minimum
clearance
800mm
maximum
water tubing
deleted for clarity
power outlet 15 mm stop-tap
(installed by plumber)
192mm
212mm
95mm
135mm
15mm min
35mm
bench thickness
1mm-48mm